Basket & Tube Filters for Water Treatment Industry

Stainless steel basket and tube filter used in water treatment, RO pre-filtration and seawater desalination
Basket & Tube Filters · Water Treatment

Stainless Steel Basket & Tube Filters for Water Treatment Industry

Raw-water intake, municipal coagulation, RO/UF/MBR pre-filtration, seawater desalination, power-plant makeup water, industrial recirculating cooling, chemical & food wastewater, reclaimed water and paper white-water — plus self-cleaning automatic backwash for non-stop service.

50–5000 µm 304 / 316L / 904L Duplex 2205 DN200–DN1500 Self-Cleaning Backwash

Industry Characteristics

Why Water Treatment Demands Heavy-Duty Stainless Pre-Filtration

Water treatment plants run very high flows for very long campaigns. The challenge is intercepting leaves, shells, sand, algae, mill scale and bulk suspended solids before they reach expensive pumps, sand filters, membranes and downstream pleated cartridges. Baskets and tube filters do the heavy lifting at intake, lift-pump inlet and pretreatment — and self-cleaning automatic backwash designs keep service running without stoppage.

water

Mega-Flow Service

Municipal & power plant intake — tens of thousands of m³/h. DN200–DN1500 multi-basket arrays.

filter_alt

RO / UF / MBR Membrane Protection

Pre-filtration upstream of membranes is the single biggest driver of membrane life.

autorenew

Self-Cleaning Backwash

Wedge-wire baskets with automatic backwash deliver non-stop service.

eco

Biofouling Defense

Intake screens intercept algae, shells and marine organisms at the source.

science

Severe Chemistry

Acidic wastewater, brackish water, chemical effluent — 904L / Duplex / Hastelloy selectable.

recycling

Long-Cycle Reuse

All-metal cleanable construction replaces disposable PP cartridges with dramatically lower TCO.

Application Coverage

16 Typical Water Treatment Applications — Equipment, Conditions, Filtration Rating & Material

From raw-water intake and municipal water plants, to RO/UF/MBR pre-filtration, seawater desalination, power-plant makeup, industrial cooling and recirculating water, chemical / food / paper wastewater, groundwater treatment, MBR and reclaimed water, all the way to self-cleaning automatic backwash systems.

← Scroll horizontally to view all columns →

Application SystemEquipmentInstall LocationService MediumWorking ConditionsContaminantsCustomer Pain PointConsequence Without FilterRatingType
Raw Water IntakeRaw Water Lift PumpPump inletRiver / lake waterHigh-flow 24×7Leaves, silt, shellsLift pump pluggingPlant shutdown1000–5000 µmBasket
Municipal Water PlantCoagulation / SedimentationPre-coagulationRaw waterHigh suspended solidsSilt, algaeHigher coagulant doseUnstable effluent quality500–2000 µmBasket
RO SystemRO HP PumpPretreatment sectionPretreated waterRO protectionSand, rustFrequent RO foulingMembrane scrap50–200 µmTube
UF SystemUF Membrane InletUpstream of UFRaw waterContinuous dutyCoarse suspended solidsSevere membrane foulingShortened membrane life100–500 µmTube
Seawater DesalinationHP Pump InletSeawater pretreatmentSeawaterHigh salinityShells, algae, siltRO membrane foulingDesalination plant shutdown50–500 µmBasket
Seawater DesalinationSeawater Lift PumpIntakeSeawaterHigh flowMarine organisms, shellsIntake pump damageSeawater supply shortfall1000–5000 µmBasket
Power Plant Makeup WaterMakeup Water PumpPump inletIndustrial waterContinuousRust, scaleRO membrane foulingPower system impact100–300 µmTube
Industrial Recirculating CoolingCooling Water PumpPump inletRecirculating cooling waterHigh flowSilt, scaleExchanger pluggingHigher energy consumption500–2000 µmBasket
Steel Mill Recirculating WaterSpray SystemUpstream of nozzleRecirculating waterHigh mill scaleMill scaleNozzle pluggingLower cooling effect100–500 µmTube
Chemical WastewaterWastewater Lift PumpPump inletIndustrial wastewaterHighly contaminatedSolid particles, crystalsPump wearEquipment failure500–3000 µmBasket
MBR SystemMBR Membrane InletPretreatmentBiological effluentHigh organicsFibers, suspended solidsMBR membrane foulingHigher cleaning frequency100–500 µmTube
Reclaimed Water ReuseReclaimed Water PumpPump inletReclaimed waterLong-cycle serviceSuspended solids, fibersPipe pluggingLower reuse rate100–500 µmTube
Food Industry WastewaterWastewater PumpPump inletFood wastewaterHigh organicsFruit pulp, fibersPump pluggingSystem shutdown500–3000 µmBasket
Paper Mill White WaterWhite-Water RecoveryCirculation pump inletWhite waterHigh fiberPulp fibersPipe pluggingLower recovery efficiency500–2000 µmBasket
Groundwater TreatmentDeep-Well PumpPump inletGroundwaterHigh sandSandPump impeller wearWell abandonment300–1000 µmTube
Self-Cleaning Automatic BackwashMain Filter ElementInside filter housingIndustrial waterAutomated dutySilt, suspended solidsFrequent cartridge replacementHigh operating cost50–3000 µmWedge Wire

Material Selection

Material Selection Guide — Service to Recommended Alloy

Material is matched to chloride load, pH and corrosive species. Use this as a starting reference; we tailor to your water analysis.

Service EnvironmentRecommended MaterialRationale
Municipal water supplySS 304Cost-effective default for general drinking-water service.
Industrial recirculating waterSS 316LHigher Mo content for better corrosion resistance.
RO pre-treatmentSS 316LLong service life in pretreated water.
UF systemSS 316LEasy backwash and chemical cleaning.
MBR systemSS 316LResistant to fouling and biological corrosion.
Chemical wastewaterSS 316L / 904L316L for general effluent; 904L for severe chemistry.
Seawater desalinationDuplex 2205Excellent chloride pitting resistance.
High-salinity wastewaterDuplex 2205High mechanical strength + chloride resistance.
Acidic wastewaterSS 904LHigh Cr / Ni / Mo resists sulfuric and hydrochloric acid.
Extreme corrosion serviceHastelloy C-276Maximum chemical corrosion resistance.

Technical Specifications

SINFT Water Treatment Basket & Tube Filter — Key Parameters

Engineering targets we hit on every water-treatment project.

Diameter Range

DN200–DN1500

For municipal & power-plant intake.

Intake Range

1000–5000 µm

Coarse intake to intercept leaves & shells.

RO Pre-Filter

50–200 µm

Final basket / tube ahead of pleated polishing.

Self-Cleaning

Wedge Wire

Automatic backwash for non-stop service.

Duplex Housing

Online Switchover

One in service, one in standby.

Open Area

40–75%

Maximum flow at minimum dP.

Construction

Fully Welded

Vibration-proof, long-life service.

Cleanability

Backwash + CIP

Cleanable, reusable across many cycles.

Customer Concerns

Top 5 Questions from Water Treatment Customers

1. Where do basket and tube filters fit in a complete water treatment plant?

add

Basket and tube filters are the first defense — at raw water intake, lift pump inlets and pretreatment ahead of RO/UF/MBR membranes. They intercept leaves, shells, sand, algae and gross debris before they reach pumps, sand filters and finally pleated cartridges for membrane polishing. A typical plant uses coarse basket (1000–5000 µm) at intake, then fine basket/tube (50–500 µm) ahead of RO.

2. What is self-cleaning automatic backwash and when should I use it?

add

For continuous high-flow water treatment (municipal water plants, large RO systems, power plant CCW) cartridge change-out becomes a bottleneck. SINFT self-cleaning wedge-wire basket filters use automatic differential-pressure or timed backwash to discharge captured solids without taking the unit offline. Result: continuous service, no scheduled stoppage and dramatically lower operating cost.

3. How big a basket do I need for municipal water or power plant intake?

add

Big. Municipal plants and power-plant cooling-water intake handle tens of thousands of m³/h. SINFT delivers DN200–DN1500 basket strainers in multi-basket parallel or duplex housing configurations with 40–75% open area, sized to deliver pump-rated flow at clean dP. For coastal intake, Duplex 2205 baskets at 1000–5000 µm intercept shells and biofouling.

4. Which material should I select for seawater desalination and acidic wastewater?

add

316L for general municipal and industrial water. Duplex 2205 for seawater desalination and high-chloride brackish water. 904L for acidic chemical wastewater service. Hastelloy C-276 for severe corrosion. Material is matched to your water analysis, especially chloride concentration, pH and dissolved oxygen.

5. Can SINFT basket and tube filters be operated as duplex housings?

add

Yes — duplex housings are the standard configuration for water-treatment plants where downtime is unacceptable. Two baskets installed in parallel allow online switchover: while one is in service, the other is cleaned and held in standby. This is the standard practice in municipal supply, RO pretreatment, power plant CCW and process cooling water service.

Related Products & Applications

Explore Related Solutions

Request a Quote — Water Treatment Basket / Tube Filters

Tell us your application (intake, RO pretreatment, desalination, cooling water, wastewater…), flow rate, water chemistry and required micron rating — our engineering team replies with a tailored specification within 24 hours.