
Stainless Steel Basket & Tube Filters for Water Treatment Industry
Raw-water intake, municipal coagulation, RO/UF/MBR pre-filtration, seawater desalination, power-plant makeup water, industrial recirculating cooling, chemical & food wastewater, reclaimed water and paper white-water — plus self-cleaning automatic backwash for non-stop service.

Industry Characteristics
Why Water Treatment Demands Heavy-Duty Stainless Pre-Filtration
Water treatment plants run very high flows for very long campaigns. The challenge is intercepting leaves, shells, sand, algae, mill scale and bulk suspended solids before they reach expensive pumps, sand filters, membranes and downstream pleated cartridges. Baskets and tube filters do the heavy lifting at intake, lift-pump inlet and pretreatment — and self-cleaning automatic backwash designs keep service running without stoppage.
Mega-Flow Service
Municipal & power plant intake — tens of thousands of m³/h. DN200–DN1500 multi-basket arrays.
RO / UF / MBR Membrane Protection
Pre-filtration upstream of membranes is the single biggest driver of membrane life.
Self-Cleaning Backwash
Wedge-wire baskets with automatic backwash deliver non-stop service.
Biofouling Defense
Intake screens intercept algae, shells and marine organisms at the source.
Severe Chemistry
Acidic wastewater, brackish water, chemical effluent — 904L / Duplex / Hastelloy selectable.
Long-Cycle Reuse
All-metal cleanable construction replaces disposable PP cartridges with dramatically lower TCO.
Application Coverage
16 Typical Water Treatment Applications — Equipment, Conditions, Filtration Rating & Material
From raw-water intake and municipal water plants, to RO/UF/MBR pre-filtration, seawater desalination, power-plant makeup, industrial cooling and recirculating water, chemical / food / paper wastewater, groundwater treatment, MBR and reclaimed water, all the way to self-cleaning automatic backwash systems.
← Scroll horizontally to view all columns →
| Application System | Equipment | Install Location | Service Medium | Working Conditions | Contaminants | Customer Pain Point | Consequence Without Filter | Rating | Type |
|---|---|---|---|---|---|---|---|---|---|
| Raw Water Intake | Raw Water Lift Pump | Pump inlet | River / lake water | High-flow 24×7 | Leaves, silt, shells | Lift pump plugging | Plant shutdown | 1000–5000 µm | Basket |
| Municipal Water Plant | Coagulation / Sedimentation | Pre-coagulation | Raw water | High suspended solids | Silt, algae | Higher coagulant dose | Unstable effluent quality | 500–2000 µm | Basket |
| RO System | RO HP Pump | Pretreatment section | Pretreated water | RO protection | Sand, rust | Frequent RO fouling | Membrane scrap | 50–200 µm | Tube |
| UF System | UF Membrane Inlet | Upstream of UF | Raw water | Continuous duty | Coarse suspended solids | Severe membrane fouling | Shortened membrane life | 100–500 µm | Tube |
| Seawater Desalination | HP Pump Inlet | Seawater pretreatment | Seawater | High salinity | Shells, algae, silt | RO membrane fouling | Desalination plant shutdown | 50–500 µm | Basket |
| Seawater Desalination | Seawater Lift Pump | Intake | Seawater | High flow | Marine organisms, shells | Intake pump damage | Seawater supply shortfall | 1000–5000 µm | Basket |
| Power Plant Makeup Water | Makeup Water Pump | Pump inlet | Industrial water | Continuous | Rust, scale | RO membrane fouling | Power system impact | 100–300 µm | Tube |
| Industrial Recirculating Cooling | Cooling Water Pump | Pump inlet | Recirculating cooling water | High flow | Silt, scale | Exchanger plugging | Higher energy consumption | 500–2000 µm | Basket |
| Steel Mill Recirculating Water | Spray System | Upstream of nozzle | Recirculating water | High mill scale | Mill scale | Nozzle plugging | Lower cooling effect | 100–500 µm | Tube |
| Chemical Wastewater | Wastewater Lift Pump | Pump inlet | Industrial wastewater | Highly contaminated | Solid particles, crystals | Pump wear | Equipment failure | 500–3000 µm | Basket |
| MBR System | MBR Membrane Inlet | Pretreatment | Biological effluent | High organics | Fibers, suspended solids | MBR membrane fouling | Higher cleaning frequency | 100–500 µm | Tube |
| Reclaimed Water Reuse | Reclaimed Water Pump | Pump inlet | Reclaimed water | Long-cycle service | Suspended solids, fibers | Pipe plugging | Lower reuse rate | 100–500 µm | Tube |
| Food Industry Wastewater | Wastewater Pump | Pump inlet | Food wastewater | High organics | Fruit pulp, fibers | Pump plugging | System shutdown | 500–3000 µm | Basket |
| Paper Mill White Water | White-Water Recovery | Circulation pump inlet | White water | High fiber | Pulp fibers | Pipe plugging | Lower recovery efficiency | 500–2000 µm | Basket |
| Groundwater Treatment | Deep-Well Pump | Pump inlet | Groundwater | High sand | Sand | Pump impeller wear | Well abandonment | 300–1000 µm | Tube |
| Self-Cleaning Automatic Backwash | Main Filter Element | Inside filter housing | Industrial water | Automated duty | Silt, suspended solids | Frequent cartridge replacement | High operating cost | 50–3000 µm | Wedge Wire |
Material Selection
Material Selection Guide — Service to Recommended Alloy
Material is matched to chloride load, pH and corrosive species. Use this as a starting reference; we tailor to your water analysis.
| Service Environment | Recommended Material | Rationale |
|---|---|---|
| Municipal water supply | SS 304 | Cost-effective default for general drinking-water service. |
| Industrial recirculating water | SS 316L | Higher Mo content for better corrosion resistance. |
| RO pre-treatment | SS 316L | Long service life in pretreated water. |
| UF system | SS 316L | Easy backwash and chemical cleaning. |
| MBR system | SS 316L | Resistant to fouling and biological corrosion. |
| Chemical wastewater | SS 316L / 904L | 316L for general effluent; 904L for severe chemistry. |
| Seawater desalination | Duplex 2205 | Excellent chloride pitting resistance. |
| High-salinity wastewater | Duplex 2205 | High mechanical strength + chloride resistance. |
| Acidic wastewater | SS 904L | High Cr / Ni / Mo resists sulfuric and hydrochloric acid. |
| Extreme corrosion service | Hastelloy C-276 | Maximum chemical corrosion resistance. |
Technical Specifications
SINFT Water Treatment Basket & Tube Filter — Key Parameters
Engineering targets we hit on every water-treatment project.
Diameter Range
DN200–DN1500
For municipal & power-plant intake.
Intake Range
1000–5000 µm
Coarse intake to intercept leaves & shells.
RO Pre-Filter
50–200 µm
Final basket / tube ahead of pleated polishing.
Self-Cleaning
Wedge Wire
Automatic backwash for non-stop service.
Duplex Housing
Online Switchover
One in service, one in standby.
Open Area
40–75%
Maximum flow at minimum dP.
Construction
Fully Welded
Vibration-proof, long-life service.
Cleanability
Backwash + CIP
Cleanable, reusable across many cycles.
Customer Concerns
Top 5 Questions from Water Treatment Customers
1. Where do basket and tube filters fit in a complete water treatment plant?
add
Basket and tube filters are the first defense — at raw water intake, lift pump inlets and pretreatment ahead of RO/UF/MBR membranes. They intercept leaves, shells, sand, algae and gross debris before they reach pumps, sand filters and finally pleated cartridges for membrane polishing. A typical plant uses coarse basket (1000–5000 µm) at intake, then fine basket/tube (50–500 µm) ahead of RO.
2. What is self-cleaning automatic backwash and when should I use it?
add
For continuous high-flow water treatment (municipal water plants, large RO systems, power plant CCW) cartridge change-out becomes a bottleneck. SINFT self-cleaning wedge-wire basket filters use automatic differential-pressure or timed backwash to discharge captured solids without taking the unit offline. Result: continuous service, no scheduled stoppage and dramatically lower operating cost.
3. How big a basket do I need for municipal water or power plant intake?
add
Big. Municipal plants and power-plant cooling-water intake handle tens of thousands of m³/h. SINFT delivers DN200–DN1500 basket strainers in multi-basket parallel or duplex housing configurations with 40–75% open area, sized to deliver pump-rated flow at clean dP. For coastal intake, Duplex 2205 baskets at 1000–5000 µm intercept shells and biofouling.
4. Which material should I select for seawater desalination and acidic wastewater?
add
316L for general municipal and industrial water. Duplex 2205 for seawater desalination and high-chloride brackish water. 904L for acidic chemical wastewater service. Hastelloy C-276 for severe corrosion. Material is matched to your water analysis, especially chloride concentration, pH and dissolved oxygen.
5. Can SINFT basket and tube filters be operated as duplex housings?
add
Yes — duplex housings are the standard configuration for water-treatment plants where downtime is unacceptable. Two baskets installed in parallel allow online switchover: while one is in service, the other is cleaned and held in standby. This is the standard practice in municipal supply, RO pretreatment, power plant CCW and process cooling water service.
Related Products & Applications
Explore Related Solutions
Basket Filters & Strainers
Back to the full product overview, specs and downloads.
Pleated · Water Treatment
Fine-polish RO security filter and PP cartridge replacement.
Water Treatment Overview
Full water-treatment portfolio across product lines.
Basket & Tube · Power Generation
CCW, boiler feed, FGD and EH oil service.
Request a Quote — Water Treatment Basket / Tube Filters
Tell us your application (intake, RO pretreatment, desalination, cooling water, wastewater…), flow rate, water chemistry and required micron rating — our engineering team replies with a tailored specification within 24 hours.